The Case for Reliable Sensors

There are plenty of examples that demonstrate how vital it is that sensors always function as intended – even under abnormal situations. Tragic events such as the recent crash of an airliner in Indonesia due to a false speedometer reading or the Turkish flight that went down close to Amsterdam Airport due to false altimeter data forcefully highlight this point.

Digitalization of power systems is already well under way. In this regard, information needed to control, meter, protect and monitor these systems is being collected by numerous sensors that transmit this data into the Cloud. Soon, there will be a situation where most components will be part of the ‘Powernet of Things’. Protocols on data exchange, such as IEC 61850, are already common and even ‘traditional’ equipment, e.g. instrument transformers, can now be hooked up using merging units to fully benefit from the digital opportunities of process buses. Special bypass lanes are reserved for emergency traffic, such as trip signals to circuit breakers or GOOSE messages, which cannot be delayed.

Advertisement
sensors The Case for Reliable Sensors Zibo ad 14

In all cases, sensors are at the interface of the physical and digital worlds. Since Cloud data is used to collect information for operation and asset management of power systems, the correct functioning of sensors must be a given. Sensors provide information on the actual status of the system and this information always has to be reliable – especially in abnormal situations from which the system needs to recover in the ‘blink of an eye’. Data analytics and mining make no sense should the source of data, namely the sensors and their hardware channels, not be trustworthy.

Advertisement
sensors The Case for Reliable Sensors CSL compressed

These days, sensors are being revolutionized with the advent of embedded software and novel physics-based technology. Traditional electromagnetic instrument transformers, for example, are being replaced by highly compact new generation technologies. These are still based on time-tested principles, named after physicists such as Faraday, Hall and Rogowski, who proposed them decades ago. Their impact is now being exploited by new materials, microelectronics and, to stress yet again, embedded software. Software, after all, can correct imperfections from non-linearities – something that was previously neither possible, nor accepted. Moreover, higher accuracy in measurements is offered. Indeed, this is necessary since power quality is now a bigger issue than in the past while degree of pollution is also higher, with more semi-conductors and non-linear loads entering the stage.

Advertisement
sensors The Case for Reliable Sensors INTEGRATED Engineering Software Mar 11

At KEMA Laboratories, a program is underway to replace certain classical, highly accurate current transformers by optical, low-power units. Test laboratories are a good place to start because stresses are extreme and the requirement for accuracy high. Reliability, by contrast, is a lower priority in a testing environment than within a live power grid. Gaining experience from these pilot efforts, suitable verification methods for such low-power instrument transformers are being development tested. In addition, a program of testing highly accurate, new generation MV energy meters will start shortly. The verification/certification track for such devices, that include embedded software and RF/GPRS data transmission, is a challenge.

Advertisement
Desma Advertisement sensors The Case for Reliable Sensors DESMA INMR OnlineAd

The pairing of microelectronics and high voltage is not always a happy union. Classical sensors output strong electrical signals along which electromagnetic disturbance is little more than ‘small noise’. As signal levels get lower, the signal to noise ratio can easily reach unacceptable levels. EMC tests cover such sensitivity but what is often forgotten is that wiring offers a preferred path of guiding unwanted transients inside otherwise well-shielded environments. Therefore, testing intelligent electronic devices (IEDs), together with the primary equipment they manage, is being seen more and more. Such an integral approach is then carried out on complete cubicles or substations under fault or otherwise onerous transients.

Advertisement
sensors The Case for Reliable Sensors OFIL banner 300X125 July1

KEMA Laboratories has decades of testing experience when it comes to electronic equipment for power systems, mainly protection relays. At present, about three-quarters of all electronic equipment submitted to a complete type test does not pass all the requirements in a single run. Obstacles can be small and overcome through minor modifications; but complete redesign is sometimes also needed. Most problems are seen in testing related to accuracy and EMC. In the case of station automation as well as protection and communication equipment, it can sometimes seem extremely difficult to meet the mechanical challenges (i.e. vibrations) as well as to satisfy all the safety requirements while also avoiding ingress of water and dust.

Advertisement
sensors The Case for Reliable Sensors BG Big Box banner 300x250

Sensors and their processing equipment, being the supplier of key information, are taking on an ever more prominent role as the source of Big Data. Therefore, it makes sense to verify functionality of sensor systems, progressing steadily not only functionally but also physically to the heart of power.

Continuity of supply is mandatory not only on power but also on data.

René Smeets                                                                                              

KEMA Laboratories