2007 Buyer's Guide & Directory
INMR Quarterly Review
Henan Machinery & Electric Import & Export Co., Ltd.
Head Office: No. 16-1 Jinshui Avenue, Zhengzhou 450003, China
Telephone: (86) 371-6586-6098 / 6586-6099
Telefax: (86) 371-6586-6088 / 6586-6087
E-Mail: liaokuo@public2.zz.ha.cn & liaokuo@cmic-henan.com
Home Page on the Internet: www.insulators.com.cn & www.cmic-henan.com

Key Contact Personnel:
Liao Kuo, Gen. Mgr. / liaokuo@public2.zz.ha.cn / liaokuo@cmic-henan.com

Year Founded: 1978 Total Employees (Head Office): 35
Total Annual Sales: USD5 to 10 million
Percent of Sales in Export Markets: 100%
Major Export Markets Served (2006): United States, Canada, Mexico, Brazil, Thailand, Greece, Australia
Range of Products Offered: Electrical Insulators, Porcelain Bushings, Surge Arresters, Fuse Cutout

INSULATORS (Porcelain, Glass, Polymeric):
Suspension Disc-Type Insulators: Glass Insulators; Porcelain & Polymer-standard type & anti-pollution types; up to 500 kV, 45-300 kN, acc. to IEC, ANSI, BS and AS stds.
Line Post Insulators: ANSI 57-1 to 57-5; IEC, AS, BS
Pin-Type Insulators: ANSI 56-1, 56-2, 56-3, 55-1 to 55-5; SLP11/180 to AWP33/920; BS
Spool Insulators: ANSI 53-1 to 53-5; BS 137; AS3608
Strain / Guy Insulators: ANSI 54-1, 54-2, 54-3, 54-4; AS3609
Cutouts: Up to 35 kV
Railway Insulators: Up to 27.5 kV
Station Post Insulators: Up to 500 kV; IEC
Insulators for Bushings: For transformers; Porcelain from LV to 500 kV or as or as per customer drawings
Switch Insulators / Bus Insulators: For SF6, vacuum, oil or as per customer drawings
Insulators for Arresters: Porcelain Up to 500 kV
Insulators for Cable Terminations: Up to 500 kV
Insulators for Fuse Cutout: Porcelain and Polymer upto 36 kV
Total Number of Factory Workers: 500
Annual Production Capacity for Porcelain: 10,000 tonnes

MATERIALS FOR INSULATORS & INSULATOR COATINGS: Caps, Pin, Spindles, Studs, Clevis, Eyes etc. for Porcelain/Glass Insulators and Polymer Insulators; Metal Assembly Parts for Transformer Bushings, Capacitor Bushings and Arrester Bushings etc. Different kind of Electrical Usage Components upon customer design, and Components for Fuse Cutout etc.

BUSHINGS: Bushing for full range of LV, MV, HV Transformer in ANSI, DIN, and other standards; Bushing for Switchgear; Bushing for Surge Arrester; Bushing for Capacitor; Bushing for Fuse Cutout; Bushing for Current Transformer can be produced as per customer specification & drawings.

ARRESTERS: Metal Oxide Gapless Lighting Arrester, Porcelain/ Polymer Bushing
Home Page Past Issue Articles Back Issues Subscription Information Index of Articles Guestbook Site Map Contact Information
INMR®
P.O. Box 95, Westmount (Montréal), Québec, Canada, H3Z 2T1
Telephone: (514) 939-9540 Telefax (514) 939-6151 Email:info@inmr.com

Copyright© 2006 INMR